By Nemtek

Nemtek Copper Clad Earth Spike 1.2m with Nut and Washer

Nemtek 10mm x 1.2m copper clad earth spike (EA-EAN/L) with a copper clad double nut and washer for a firm HT cable connection. Earths an electric fence energizer. 0.93kg. Sold singly.

  • 10mm x 1.2mRod size
  • Copper cladFinish
  • Double nutCopper clad nut and washer
  • 0.93kgWeight
Regular price R 65.00
Collect at a branch, no charge
  • Alectra Hatfield 648 Jan Shoba Street, HatfieldMon to Fri 07:30 to 17:00, Sat 08:00 to 17:00
    Get directions
  • Alectra Wonderboom Braam Pretorius Street, WonderboomMon to Sun 08:00 to 16:45
    Get directions

Choose Pickup at checkout and we message you when your order is ready to collect.

The Nemtek earth spike is a 10mm x 1.2m copper clad rod with copper clad nuts and a washer, used to earth an electric fence energizer. An energizer needs a good earth. The shock an intruder gets, and the alarm the energizer raises, both depend on current finding its way back through the earth wires and the earth spike. With a poor earth the shock is weaker and the energizer's readings cannot be trusted. Drive the spike into the ground, leave enough above the surface to clamp the HT cable under the double nut, and run that cable to the earth terminal on the energizer.

What's in the box

  • 1 copper clad earth spike, 10mm x 1.2m, pointed
  • Copper clad double nut and washer on the threaded end

Why the energizer earth matters

Nemtek's Merlin Stealth installer manual asks for the earth electrode to go at least 1m into the ground, and this spike gives you 1.2m to work with. The manual also keeps the fence earth away from other earth systems, so the house earth and the fence earth stay separate. Nemtek's manuals do not give a spikes-per-joule rule: fit the number of spikes the manual for your energizer asks for. Our fence kits come with four, and the Nemtek Double Pole Lightning Protection is best placed within 2m of the earth spike it discharges into.

Connecting the HT cable

Nemtek names this spike with its nut and washer for a reason: the copper clad double nut clamps the stripped end of the slimline HT cable firmly to the rod, so the earth connection stays tight. Use the same HT cable for the live lead-out.

Works with every energizer we sell

The Nemtek Merlin Stealth M18S, Merlin Stealth M28S, Wizord 4i, Druid 15 LCD and DTS Megashock 5 all need an earth spike or a set of them. Alectra supplies the equipment only. The fence must be installed and certified by a registered electric fence installer.

Courier anywhere in South AfricaR160 for orders up to 10 kg. Heavier orders are priced by weight at checkout. Free courier on orders of R8,000 or more, up to 10 kg.
Collect in Pretoria at no chargeChoose collection at checkout and pick up at Hatfield or Wonderboom.
Genuine stockSupplied through the official South African distributors, with the supplier warranty.
Key features
  • 1.2m long. Enough rod to put at least 1m into the ground, as Nemtek's installer manual asks, with the threaded end above the surface.
  • Copper clad rod. Nemtek lists the finish as copper cladded. It is not solid copper.
  • Double nut and washer. Copper clad nuts and washer clamp the HT cable to the rod for a connection that stays tight.
  • Nemtek part EA-EAN/L. The same spike Nemtek lists for its own energizers.
  • The earth is half the fence. The shock and the alarm both depend on current returning through the earth wires and this spike.
  • Fit as many as the manual asks. There is no per-joule rule. Follow the installer manual for your energizer; our kits come with four spikes.
  • Pairs with lightning protection. Nemtek's Double Pole Lightning Protection sends a strike into the earth spike and is best placed within 2m of it.
Specifications
Nemtek nameEarth Spike, Copper, 1.2m (nut/washer)
Nemtek codeEA-EAN/L
Diameter10mm
Length1.2m
FinishCopper cladded
Cable connectionCopper clad double nut and washer
Weight0.93kg
Depth in the groundAt least 1m (Nemtek installer manual)
Warranty1 year (Nemtek fencing components)
Sold asEach
Pack contents1 spike with double nut and washer
Not in the box
  • HT cable
  • Lightning diverter
  • Energizer
Manuals and documents
Questions people ask
Is the earth spike solid copper?

No. Nemtek lists the finish as copper cladded: a copper layer over the core rod. That is the normal construction for a fence earth spike.

How deep does it go?

Nemtek's Merlin Stealth installer manual asks for at least 1m in the ground. Drive the spike in and leave the threaded end above the surface for the cable.

How many spikes do I need?

Follow the installer manual for your energizer. Nemtek gives no per-joule rule, and some of its manuals ask for more than one spike. Our electric fence kits come with four.

How do I connect the HT cable to it?

Strip the HT cable, slip the bare end under the washer and tighten the copper clad double nut on it. Run the cable to the earth terminal on the energizer.

Can I use the house earth instead?

No. Nemtek's manual keeps the fence earth away from other earth systems. Give the energizer its own spike or spikes and keep them the distance the manual sets.

Does a poor earth matter if the fence voltage looks fine?

Yes. Without a good earth the shock is weaker and the energizer's readings cannot be trusted. If a fence seems weak, the earth is one of the first things an installer checks.

Who installs it?

Your registered electric fence installer, who also measures the earth and certifies the fence. Alectra supplies the spike only.

Need it fitted? Alectra Solutions supplies product only. Ask the branch and we will point you to installers in Pretoria.